Microlab Services

Alarmes e erros Still EXUS tracção

Lista dos códigos de alarme e erro do controlador Still EXUS tracção: significado, causas prováveis e diagnóstico da avaria.

Still Still EXUS/CX/EXDS tracção

200

WATCHDOG

Ver →
201

STBY I HIGH

Ver →
202

CAPACITOR CHARGE

Ver →
203

CONTACTOR DRIVER

Ver →
204

DRIVER SHORTED

Ver →
205

COIL SHORTED

Ver →
206

ANALOG INPUT

Ver →
207

POWER MOS SHORTED

Ver →
208

SLAVE ALARM 1

Ver →
209

NO POS-GEN EF

Ver →
210

WATCHDOG PUMP

Ver →
211

NO CAN MESSAGE 2

Ver →
212

VMN LOW

Ver →
213

LOGIC FAILURE #1

Ver →
217

INCORRECT START

Ver →
218

ANALOG INPUT PUMP

Ver →
219

PUMP VMN LOW

Ver →
220

PUMP VMN HIGH

Ver →
221

BATTERY NOT OK

Ver →
222

LOGIC FAILURE #2

Ver →
224

HW FAULT

Ver →
225

DRIVER SHORTED EVP

Ver →
226

(reserved)

Ver →
227

CONTACTOR CLOSED

Ver →
228

VMN HIGH

Ver →
229

WRONG SET BATTERY

Ver →
231

WRONG ZERO

Ver →
232

CAN BUS KO TILLER

Ver →
235

HARDWARE FAULT PUMP

Ver →
236

AUX DRIVER OPEN

Ver →
237

NO CAN MESSAGE 5

Ver →
238

AUX DRIVER SHORTED

Ver →
239

CONTACTOR OPEN

Ver →
240

SLAVE ALARM 3

Ver →
241

SLAVE ALARM 4

Ver →
243

SAFETY FEED

Ver →
244

TRUCK TYPE CHANGE

Ver →
248

ENCODER ERROR

Ver →
249

LOGIC FAILURE #3

Ver →
250

SENSOR RAIL KO

Ver →
251

STBY I HIGH (W)

Ver →
252

CAPACITOR CHARGE (W)

Ver →
253

CONTACTOR DRIVER (W)

Ver →
254

DRIVER SHORTED (W)

Ver →
255

COIL SHORTED (W)

Ver →
256

ANALOG INPUT (W)

Ver →
257

POWER MOS SHORTED (W)

Ver →
258

THERMIC SENSOR KO

Ver →
259

POS-GEN EF (W)

Ver →
260

EEPROM KO

Ver →
261

NO CAN MESSAGE 2 (W)

Ver →
262

VMN LOW (W)

Ver →
263

CONTROLLER TEMPERATURE

Ver →
264

STEERING HAZARD

Ver →
265

SHORTED VALVE

Ver →
266

FORW+BACK

Ver →
267

INCORRECT START (W)

Ver →
268

ANALOG INPUT PUMP (W)

Ver →
269

PUMP VMN LOW (W)

Ver →
270

PUMP VMN HIGH (W)

Ver →
271

BATTERY NOT OK (W)

Ver →
272

LOGIC FAILURE #2 (W)

Ver →
273

PUMP STBY I HIGH

Ver →
274

HW FAULT (W)

Ver →
275

DRIVER SHORTED EVP (W)

Ver →
276

WEAK BATTERY

Ver →
277

CONTACTOR CLOSED (W)

Ver →
278

VMN HIGH (W)

Ver →
279

WRONG SET BATTERY (W)

Ver →
280

CURRENT SENSOR LOW PUMP

Ver →
281

WRONG ZERO (W)

Ver →
282

CAN BUS KO TILLER (W)

Ver →
283

GRAY CODE

Ver →
284

LIFT+LOWER

Ver →
285

HARDWARE FAULT PUMP (W)

Ver →
286

AUX DRIVER OPEN (W)

Ver →
287

NO CAN MESSAGE 5 (W)

Ver →
288

AUX DRIVER SHORTED (W)

Ver →
289

CONTACTOR OPEN (W)

Ver →
290

MOTOR TEMPERATURE

Ver →
291

EEPROM KO PUMP

Ver →
292

PUMP INCORRECT START

Ver →
293

DRIVER KO EVP

Ver →
294

DEADMAN MISMATCH

Ver →
295

VALVE CONTACTOR DRIVER

Ver →
296

VALVE DRIVER SHORTED

Ver →
297

WRONG PARAMETER

Ver →
298

ENCODER ERROR (W)

Ver →
299

LOGIC FAILURE #3 (W)

Ver →

Empilhador parado com este alarme?

Diga-nos a marca, o modelo e o código — respondemos com o próximo passo.

Ligar +351916408509 Email Formulário

WhatsApp